SAMPOTRACK SYSTEMS
Menu
MAGNETIC TRACK / PRODUCT FAMILY

M25 Control Devices: 2.4G and Bluetooth

Choose M25 control devices by the desired user action and the matching device description. The family includes 2.4G switches, a dual-channel gateway, remote controls and a Bluetooth panel. Keep protocol and physical form together in the request.

Send Your Track Layout
M25 Control Devices: 2.4G and Bluetooth — selection details
Panel switchYZ-KG / 2.4G
Dual-channel gatewayYZ-WG / 2.4G
Remote variantYZ-YK / 2.4G
Remote variant descriptionYZ-YK / Bluetooth
Panel remoteYZ-YK2 / Bluetooth
01

Write the daily operation

Describe which lights should switch together and who will operate them. A clear use pattern is a better starting point than selecting the smallest controller on appearance alone. Write a short operating sequence for entering, occupying and leaving the room. An entrance action may bring on circulation, while a display area or reading zone may need an independent group. Mark those groups on the M25 lighting plan before assigning devices. Then identify the corresponding panel, remote and any gateway proposed for the selected lamps. A control system that looks simple on a component list can become confusing if the same action produces different effects in adjacent zones. Keep the brief in ordinary room terms so the buying team and the future user can review it. The device schedule should answer those actions with an identified combination rather than a broad promise of wireless convenience.

02

Separate device forms

A wall panel and a handheld remote suit different routines. Consider where a user enters the room and whether the controller should stay in a fixed place. YZ-KG is the listed 2.4G panel switch, while the remote directions include handheld and panel forms. Decide where the user needs a dependable fixed interface and where a movable device is appropriate. A handheld remote can be misplaced or carried away from the room, so consider how ordinary entry and exit will work if it is unavailable. A panel needs a suitable wall location beside doors and other controls. Request the selected device's own installation and operating information before fixing that position. The form of the interface affects daily behavior as much as its appearance, and the corresponding communication description must remain part of the final choice when panel and remote alternatives are compared.

03

Identify protocol alongside name

Include 2.4G or Bluetooth with the intended remote description. The physical device and communication description together communicate the requested variant more clearly. The table includes YZ-YK with both 2.4G and Bluetooth descriptions, so the identifier alone is ambiguous. Preserve the communication description alongside the model in every quotation revision and order line. YZ-YK2 is identified as a Bluetooth panel remote and should retain that full description as well. A purchasing system that truncates these names can turn distinct requested variants into apparently identical items. Ask for the actual proposed device combination and matching lamp information rather than assuming the shared identifier resolves compatibility. Keep photographs or product sheets with the accepted written schedule where helpful. The objective is an order that remains clear even after the original designer is no longer present to interpret a shortened remote name.

04

Treat the gateway as a component

Its location, power arrangement and role belong in the system discussion. Ask for the matching device combination for the selected luminaires rather than adding a gateway in isolation. YZ-WG is the listed 2.4G dual-channel gateway. Identify the role it is expected to perform in the room's proposed control arrangement and request the corresponding device and luminaire combination. Its dual-channel description should not be expanded into an assumed list of supported behaviors without the selected product information. Show the intended location and ask for the actual power and installation requirements so the electrician can coordinate them with the building. A gateway is another component occupying space, with service and commissioning needs to review. Keep it on the device drawing rather than treating it as an invisible addition that automatically makes unrelated wireless products form a working system when the order arrives on site.

05

Keep the wall composition coherent

A panel may sit beside other building controls. Compare its size, finish and placement against the room elevation before choosing the final user interface. Place the proposed panel beside the actual door trim, switch plates and other building interfaces in an elevation. Check reach, visibility and the movement of the door rather than centering the device on an empty patch of wall in plan. Request the selected panel's dimensions and finish information before coordinating the wall arrangement. A panel remote and a wired building switch may have different installation requirements even when their visual roles seem similar, so follow the chosen device information. Keep the communication description with that elevation to protect the intended variant. The wall composition should remain intelligible to occupants, with lighting actions easy to locate instead of scattered among visually similar controls with unexplained purposes.

06

Review the intended grouping

A control plan should explain how the room is used, including areas that operate independently. Supply this plan with the lighting layout so device selection follows actual behavior. Label each proposed lighting group by the area or task it serves: entrance, display, meeting table or another meaningful room description. Mark which groups should act together and which need independent operation, then ask for the matching M25 device proposal. Do not infer the grouping behavior solely from a model name or the words dual-channel. Review the actual selected combination and retain its commissioning information. If the layout changes, update the grouping plan before treating the original control order as unchanged. A lamp moved to another rail zone may also alter the user's expected action. The accepted plan should explain the room's routine clearly enough that installer settings and user instructions can be checked against the same intended behavior.

07

Request a coordinated control review

Identify the rail and luminaire choices together with the desired switching actions. Ask for the corresponding device schedule and technical sheets before placing the system order. Send the selected rail and lamp list with the operating sequence and group drawing. Identify YZ-KG, YZ-WG, YZ-YK or YZ-YK2 only with the corresponding requested form and 2.4G or Bluetooth description. Ask for the complete device schedule, installation information and commissioning requirements for that proposed assembly. If another variant is offered, compare its effect on wall locations and user actions as well as its price. Keep any unresolved operating choice visible rather than allowing a generic remote allowance to close the quotation. A coordinated request lets procurement preserve the exact control combination and gives the project team a clear basis for checking the installed room before handover to its everyday users.

Bring the selection into the room: M25 Control Devices: 2.4G and Bluetooth

Describe the M25 room actions before selecting the control devices. Mark the intended groups, fixed interface positions and any need for a handheld remote. Keep 2.4G or Bluetooth beside each requested designation, especially where YZ-YK appears in more than one variant. Request the matching device and luminaire combination with its installation and commissioning information. The accepted control schedule should remain understandable as a set of ordinary actions in the finished room.

Continue this project: M25 Control Devices: 2.4G and Bluetooth

SYSTEM / SELECTION

A rail. The right light. A complete plan.

Share your ceiling drawing and the lighting tasks you need to solve.

Request a Magnetic Track System Quote