SAMPOTRACK SYSTEMS
Menu
MAGNETIC TRACK / PRODUCT FAMILY

M26 Track Accessories and DC48V Power

M26 accessories coordinate geometry, electrical continuity and power entry. Straight and corner parts shape the route, conductive modules connect the electrical path, and DC48V supplies complete the driver-fed arrangement.

Send Your Track Layout
M26 Track Accessories and DC48V Power — selection details
A/B joinsYZ-M26A-LC / LV / I / L / T / X
Input moduleYZ-M26-X
Conductive joinsYZ-M26-I / YZ-M26-L
SuppliesYZ-M26-100W / YZ-M26-200W DC48V
Storage boxYZ-M26-H
01

Separate physical and electrical joints

A route can appear continuous while still needing a conductive connection. Review both functions at every splice and corner when preparing the accessory schedule. Mark the physical rail joint on the plan, then identify how electricity crosses that same position using the selected component documentation. The table lists conductive YZ-M26-I and YZ-M26-L joins alongside A/B joining directions; do not treat every similarly shaped part as performing every connection job. A finished ceiling can hide an omitted conductive link behind an apparently neat mechanical corner. Give each junction a reference and put the associated parts beneath that reference in the bill of materials. Ask the installer to review the diagram before the order is issued. The check should follow the actual rail route through changes of direction rather than stop after confirming that the straight sections add up to the architectural line.

02

Identify the profile first

A/B joining parts and the C/D directions belong with their relevant rail sections. Include the intended profile in every connection request to keep the component list coherent. A connector photographed beside an M26 rail is insufficient identification when several section directions appear in the wider family. Write the selected rail designation on the junction detail, then name the proposed YZ-M26A-LC, LV, I, L, T or X part where applicable. Ask for its matching technical information and show the installed orientation, especially at a corner seen from below. Keep ceiling mounting and electrical crossing requirements in the same detail without assuming one joining part resolves both. If the rail profile changes during architectural review, revisit the joining schedule as a separate task. Reusing the old accessories beneath a revised profile heading can leave the procurement list looking complete while its physical interfaces no longer agree.

03

Mark the input location

The feed should be coordinated with the supply and the accessible cable route. Put those locations on the same drawing rather than leaving the electrical entry to site improvisation. Identify YZ-M26-X as the input module where selected, and retain its role in the schedule separately from any crossing or joining descriptions. Show where the incoming cable approaches the rail and whether it passes through a ceiling opening, enclosure or visible surface route. A rail centered perfectly on the room may still place its feed directly against a beam or finished joinery panel. Ask the electrical contractor to review the proposed entry under the selected installation instructions. Keep the route accessible where service is required, and coordinate visible cable treatment with the architect. Power entry is part of the installed appearance as well as an electrical connection, so it deserves its own location reference and drawing detail.

04

Plan the supply enclosure

The storage box and supply create another visible or concealed element in the installation. Check its placement and access alongside the room's ceiling detail. YZ-M26-H should appear on the drawing where that storage-box direction is selected, with the relevant supply dimensions checked against the available space. A nominal ceiling void is not necessarily usable if ducts, framing or a sloping structural surface occupy it. Draw the opening through which the selected component can be installed and later removed, rather than showing only its final resting position. Keep the YZ-M26-100W or 200W DC48V supply description attached to the proposal and request the appropriate installation information. A concealed location must remain serviceable after paint and joinery are complete. Where the box is visible, compare its edges and cable entry with the rail composition so the supporting electrical equipment does not become an unplanned ceiling feature.

05

Give the designer a luminaire list

Power selection depends on the actual lighting schedule and the electrical arrangement. Provide the chosen module ratings rather than estimating the supply from rail length alone. A short run crowded with several luminaires can present a different demand from a long run carrying only a few heads. List each installed model, quantity and rating, then ask the electrical designer to review the proposed DC48V arrangement against the selected supply documentation. The YZ-M26-100W and YZ-M26-200W descriptions identify available supply directions, not an automatic answer for every rail of a particular size. Include input positions and branches so the designer can assess the complete route. If later additions are anticipated, describe them explicitly rather than hiding an arbitrary allowance in the quantity sheet. Retain the accepted supply selection with the luminaire list so a lighting revision prompts a corresponding review of the power arrangement.

06

Document branch geometry

T and X layouts need clear identification of route direction and connected sections. A marked diagram helps procurement distinguish the required joining pieces from spare accessories. Label each arm of a branch and identify which straight rail sections meet there; a cross drawn as a thin architectural line cannot communicate all the physical and conductive parts needed below the ceiling. The YZ-M26A joining list includes T and X directions, while the selected rail profile still governs the relevant connection detail. Ask for the matching assembly drawing and verify the orientation against the actual ceiling route. Mark input and continuation paths separately where the electrical design requires them. Avoid ordering an equal quantity of every connector type as a general contingency. A branch-by-branch bill of materials makes missing parts easier to spot and allows spare accessories to be requested intentionally without confusing them with components needed for the initial installation.

07

Review the complete package

Request the rail, joins, input modules and supply components together. Retain that coordinated list for installation and for later requests for matching parts. Begin the package review at the YZ-M26-X input and follow the drawn route through every straight joint, corner and branch to its final termination. Compare each junction reference with the selected profile and the relevant joining description. Check the YZ-M26-H enclosure placement alongside the chosen 100W or 200W DC48V supply, using the actual technical sheets for access and installation decisions. Keep the luminaire schedule with this accessory list; it explains the connected load and prevents the power package from becoming detached from the lighting design. Ask any alternative proposal to identify the original item it replaces. At handover, retain the final component descriptions and access positions so a future extension starts from an identifiable assembly rather than a ceiling photograph.

Bring the selection into the room: M26 Track Accessories and DC48V Power

Trace the M26 installation from its input to its last rail section before placing the accessory order. Record mechanical and conductive jobs separately, tie every join to the selected profile, and show the storage box and DC48V supply where they can be serviced. Add the actual luminaire ratings to the request. The completed drawing should account for each corner, branch and feed with named components that can be checked against the delivered package.

Continue this project: M26 Track Accessories and DC48V Power

SYSTEM / SELECTION

A rail. The right light. A complete plan.

Share your ceiling drawing and the lighting tasks you need to solve.

Request a Magnetic Track System Quote